SKU: EL1904HP30001026
$220.50
Add to wishlistDatakom DKG-317 Generator Manual and Remote Start Control Panel/Controller
Description:The DKG-317 is a comprehensive generator control unit designed to start and stop the generating set both manually and remotely. The manual control is made using the pushbuttons on the front panel. The remote control is made via the REMOTE START The unit is available with MPU or CANBUS versions.The CANBUS version connects to ECU controlled electronic engines providing engine control, protection and instrumentation without extra senders. The unit is able to initiate modem calls and send SMS messages in fault conditions through external modems.The unit provides a comprehensive set of digitally adjustable timers, threshold levels, input and output configurations, operating sequences and engine types. All programs may be modified via front panel pushbuttons, and do not require an external unit. Last 100 faults are stored in the event log file. The event log includes not only the date-time information, but also a comprehensive list of measured genset parameters at the time that the fault has occurred. The WINDOWS based RAINBOW program allows remote monitoring and control The unit supports MODBUS protocol enabling communication with PLCs and building management systems. The MODBUS protocol is also supported through GSM and PSTN modems.Measurements:Generator Volts:L1-N, L2-N, L3-NGenerator Volts:L1-L2, L2-L3, L3-L1Generator Amps:L1, L2, L3Generator total kWGenerator total pfGenerator FrequencyEngine rpmBattery VoltageEngine Coolant TemperatureEngine Oil Pressure Fuel LevelEngine Oil TemperatureSpecification:Alternator voltage: 0 to 300 V-AC (Ph-N)Alternator frequency: 0-100 Hz.DC Supply Range: 9.0 to 33.0 V-DCCranking dropouts: survives 0 V for 100ms.Typical Standby Current: 100 mA-DCMaximum Operating Current: 250 mA-DC (Relay outputs open)DC Outputs: 10A @ 28VCharge excitation: min 2 WattsMagnetic pickup input:: 0.5 – 30 V-AC.Magnetic pickup frequency: 10 KHz max.Current inputs: from CTs, .../5A. Max load 0.7VA per phase.Analog input range: 0-5000 ohms.Serial port: RS-232, 9600 bauds, no parity, 1 bit stopOperating temp.: -40°C (-40°F) to 70°C (158°F).Storage temp.: -55°C (-67°F) to 80°C (176°F).Maximum humidity: 95% non-condensing.Dimensions: 172x 134 x 46 mm (WxHxD)Panel Cut-out Dimensions: 151x111 mm minimum.Weight: 300 g (approx.)Case Material: High Temperature ABS/PC (UL94-V0)IP Protection: IP65 from front panel, IP30 from the rearInstallation: Flat surface mounting on a Type 1 enclosure.CE Conformity reference standards:EN 61010 (safety requirements)EN 61326 (EMC requirements)UL / CSA Conformity: certificate # 20110527-E314374UL 508, Edition 17UL 2200, 1st Edition.UL 840 Edition 3CSA C22.2 NO. 14 - Edition 10
Reviews
There are no reviews yet.